ProductsLN-series burnersCapacity/range
     

Capacities and dimensions of burners of the LN-series

   

The standard delivery range of burners of Thermeta Service BV varies from 50 kW to 16 MW. Capacities outside this range can be offered on request.

LN type Burner
load
[kW] gas
Max. gas [m3/h]  1) Min. gas [m3/h]  1)

Oil 
[ltr/h]  2)

Boiler power
[kW ] 3)
Max. steam capacity
[kg/h]  4)
LN 5 616 70 23 58 582 855
LN 7.5 924 105 26 86 872 1283
LN 10 1231 140 35 115 1163 1710
LN 12.5 1539 175 44 144 1453 2138
LN 15 1847 210 53 173 1745 2565
LN 17.5 2155 245 50 201 2035 2993
LN 20 2463 280 48 230 2326 3420
LN 25 3079 350 60 288 2908 4275
LN 30 3694 420 70 345 3489 5130
LN 35 4310 490 82 403 4071 5986
LN 40 4926 560 94 461 4652 6841
LN 50 6157 700 118 576 5815 8551
LN 60 7388 840 140 691 6978 10261
LN 70 8620 980 140 806 8141 11971
LN 80 9851 1120 140 921 9304 13681
LN 90 11083 1260 158 1036 10467 15391
LN 100 12314 1400 275 1151 11630 17102
LN 110 13546 1540 193 1276 12793 18812
LN 120 14777 1680 210 1382 13956 20522
LN 130 16008 1820 228 1496 15119 22232
LN 140 17240 1960 245 1611 16282 23942
LN 150 18471 2100 263 1727 17445 25652
LN 160 19703 2240 280 1842 18608 27362

1) Groningen gas 31.65 MJ/m3(0)
2) Oil 38.49 MJ/ltr.
3) Based on 94.4% efficiency (Hi)
4) Based on LP steam / boiler total efficiency 90% (Hi) / T (water in) 20°C / Thermeta does not guarantee the total efficiency of the boiler
5) Gas train safety shut-off valves: Dimensions based on standard gas pressure. Burners can be adjusted for deviating gas pressures (dimensions of the gas train will deviate then)
6) The gas pressure measured on the gas inlet flange of the gas train is based on the design combustion atmosphere pressure. For the required gas pressure increase the pressure by the extra combustion atmosphere pressure.

Electric burner switch panel: dimensions (w x h x d): 1000 x 1000 x 300 (standard model)
Standard electricity supply: 400 V / 3 ph + N + E / 50 Hz (other voltages/frequency on request)
All standard gas burners have been designed for a maximum gas pressure of 350 mbar. The gas pressure may not exceed this pressure. The burners can be adjusted for higher gas pressure values on request.